How does the Carter excavator adjust the hydraulic pump

Hydraulic pump adjustment No matter what brand of excavator, even if it is recognized as a steel giant's Carter excavator, immediately under the premise of proper maintenance, after more than 10,000 hours, it will also face hydraulic pump wear, slow speed of the whole car, need Fine-tuning the dilemma! It is no stranger to adjust the hydraulic pump to the old drivers, but you should pay attention to the adjustment of the hydraulic pump. First, you need to determine whether the hydraulic oil has deteriorated and the hydraulic oil filter has expired without good maintenance.


In the case of ensuring that all other components are normal, and it can be accurately judged that the hydraulic pump regulator has failed, the hydraulic pump can be adjusted. Otherwise, the hydraulic pump can be adjusted blindly, which not only solves the problem, but also complicates the problem.


The adjustment of the hydraulic pump is divided into two situations, one is the constant power control adjustment of the hydraulic pump, and the other is the maximum output flow adjustment of the hydraulic pump. The old drivers must check the number when making adjustments (this article takes the Carter 320C as an example)


The hydraulic pump constant power control adjustment should be adjusted by one pump regulator and one pump regulator during adjustment, and another hydraulic pump to be adjusted cannot be loaded, otherwise the adjustment will be incorrect.


▊First stage adjustment: First adjust the first stage of the constant power control of the right pump flow, loosen the lock nut 2, and turn the adjustment screw 1 to adjust the pump output flow. Clockwise adjustment increases pump output flow and counterclockwise adjustment reduces pump output flow. The above is adjusted under the pressure range of 11800KPA to 19600KPA. (1000kpa=10kg/cm2)


▊ Second stage adjustment: Loosen the lock nut 3 and turn the adjustment screw 4 to adjust the output flow of the pump. Clockwise adjustment increases pump output flow and counterclockwise adjustment reduces pump output flow. The above is adjusted under the pressure range of 27500KPA to 34300KPA. (1000kpa=10kg/cm2)